• product_banner

HCG Rapid Test Kit (Lateral chromatography)

Short Description:

Specimen Urine Format Strip/Cassette/Midstream
Sensitivity 99.55% Specificity 99.26%
Trans. & Sto. Temp. 2-30℃ / 36-86℉ Test Time 3 mins
Specification 1 pcs strip/box     1 pcs cassette/box  1 pcs midstream/box25 pcs strip/box   25 pcs cassette/box  25 pcs midstream/box

Product Detail

Product Tags

Product details

Intended Use
HCG Rapid Test Kit (Lateral chromatography) is to be used for in vitro qualitative diagnostic of human chorionic gonadotropin (HCG) in urine samples. The test is only to be used by medical professionals.

Test Principle
The kit is immunochromatographic and uses double-antibody sandwich method to detect HCG, It contains Colored spherical particles labeled HCG monoclonal antibody 1 that is wrapped in conjugate pad, HCG monoclonal antibody II that is fixed on the membrane, and quality-control line C.

detail

Main Contents

Components provided are listed in the table.

Materials provided

 

Quantity(1 Test/Kit)

 

Quantity(25Tests/Kit)

 

Strip Test Kit 1 test 25 tests
Urine Cup 1 piece 25 pcs
Instructions For Use 1 piece 1 piece
Certificate of Conformity 1 piece 1 piece
Cassette Test Cassette 1 test 25 tests
Dropper 1 piece 25 pcs
Urine Cup 1 piece 25 pcs
Instructions for Use 1 piece 1 piece
Certificate of Conformity 1 piece 1 piece
Midstream Test Midstream 1 test 25 tests
Urine Cup 1 piece 25 pcs
Instructions for Use 1 piece 1 piece
Certificate of Conformity 1 piece 1 piece

Operation Flow

For Strip:
1.Take out the test strip from the original aluminum foil bag and insert the reagent strip into the urine sample in the direction of the arrow for 10 seconds.
2.Then take it out and put it flat on a clean and flat table and start timer.
3.Read the results within 3-8 minutes and determine it invalid after 8 minutes.

detail

For Cassette:
1.Take out the test strip from the original aluminum foil bag and insert the reagent strip into the urine sample in the direction of the arrow for 10 seconds.
2.Then take it out and put it flat on a clean and flat table and start timer.
3.Read the results within 3-8 minutes and determine it invalid after 8 minutes.

detail

For Midstream:
1.Take out the test strip from the original aluminum foil bag and insert the reagent strip into the urine sample in the direction of the arrow for 10 seconds.
2.Then take it out and put it flat on a clean and flat table and start timer.
3.Read the results within 3-8 minutes and determine it invalid after 8 minutes.

detail

Result Interpretation

detail

Negative result
Colored band appear at control line (C) only. It indicates that the negative
result.

Positive Result
Colored bands appear at both test line (T) and control line (C). It indicates a positive result for the detection of HCG.

Invalid Result
No visible colored band appears at control line after performing the test. The directions may not have been followed correctly. It is recommended that the
specimen be re-tested.

Order Information

Product Name Cat. No Size Specimen Shelf Life Trans. & Sto. Temp.
HCG Rapid Test Kit (Lateral chromatography) B007S-01
B007S-25
B007C-01
B007C-25
B007M-01
B007M-25
1 pcs strip/box
25 pcs strip/box
1 pcs cassette/box
25 pcs cassette/box
1 pcs midstream/box
25 pcs midstream/box
Urine 24 Months 2-30℃ / 36-86℉

  • Previous:
  • Next:

  • Write your message here and send it to us