Wholesale Quality Tuberculosis Antibody Test Kits For Sale,
Tuberculosis, Tuberculosis Antibody, Tuberculosis diagnosis, Tuberculosis test,
Intended Use
This product is suitable for the qualitative clinical screening of serum/plasma/whole blood samples for the detection of antibodies against Mycobacterium tuberculosis. It is a simple, rapid and non-instrumental test for the diagnosis of tuberculosis caused by Mycobacterium tuberculosis.
Test Principle
Tuberculosis Antibody Test Kit (Immunochromatographic Assay) is a lateral flow chromatographic immunoassay. It has two pre-coated lines, “T” Test line and “C” Control line on the nitrocellulose membrane.
The purified specific recombinant Mycobacterium tuberculosis antigen is immobilized on the nitrocellulose membrane at the Test Line region and another specific Mycobacterium tuberculosis Ag conjugated to the colloidal gold is coupled on the label pad.
Materials / provided | Quantity(1 Test/Kit) | Quantity(5 Tests/Kit) | Quantity(25 Tests/Kit) |
Test Kit | 1 test | 5 tests | 25 tests |
Buffer | 1 bottle | 5 bottles | 25/2 bottles |
Dropper | 1 piece | 5 piece | 25 piece |
Specimen Transport Bag | 1 piece | 5 pcs | 25 pcs |
Disposable Lancet | 1 piece | 5 pcs | 25 pcs |
Instructions For Use | 1 piece | 1 piece | 1 piece |
Certificate of Conformity | 1 piece | 1 piece | 1 piece |
Collect human Serum/Plasma/Whole blood properly.
1. Remove an extraction tube from the kit and a test box from the film bag
by tearing the notch. Open the inspection card aluminum foil bag. Remove the test card and
place them horizontally on a platform.
2. Use a disposable pipette, transfer 4μL serum (or plasma), or 4μL whole blood into the sample well on the test cassette.
3. Open the buffer tube by twisting off the top. Put 3 drops (about 80 μL) of assay diluent into the assay diluent well round shaped. Start counting.
Read the result at 5-10min. Results after 10 minutes are invalid.
Negative result
Only the quality control C line appears and the detection T line does not show color, it indicates that there is no TB antibody in the specimen.
Positive Result
Both the quality control C line and the detection T line appear, and the
result is positive for TB antibody.
Invalid Result
No visible colored band appears at control line after performing the test.
Review the test procedure and repeat the test using a new test device.
Product Name | Cat. No | Size | Specimen | Shelf Life | Trans. & Sto. Temp. |
Tuberculosis Antibody Test Kit (Immunochromatographic Assay)) | B022C-01 | 1test/kit | Serum/Plasma/Whole Blood | 18 Months | 2-30℃ / 36-86℉ |
B022C-05 | 5 tests/kit | ||||
B022C-25 | 25 tests/kit |
Bioantibody Tuberculosis Antibody Test Kit is a commercial quality test kit that can be used to detect TB disease in cattle, goats and pigs. It is a rapid test for the qualitative detection of antibodies to Mycobacterium tuberculosis in serum.
The Bioantibody Tuberculosis Antibody Test Kit is a superior quality TB antibody test kit that is used to detect the presence of antibodies to Mycobacterium tuberculosis in human serum and plasma. The kit has been designed as a screening test for active tuberculosis disease, latent tuberculosis infection, and prior BCG vaccination. This assay has been developed by experts in the field of immunology and microbiology at Bioantibody Inc., a leading manufacturer of high-quality immunoassays.
Bioantibody Tuberculosis Antibody Test Kit
A simple, one-step test that uses the principle of immunoassay to detect antibodies specific to Mycobacterium tuberculosis in human serum, plasma, or whole blood. This kit is for research use only and not for diagnostic, therapeutic, or other clinical purposes.
This kit uses a solid phase enzyme immunoassay (EIA) technique with monoclonal antibodies (MAbs) to detect Tuberculin Skin Test (TST) positive subjects. With this kit, tests can be completed in approximately 30 minutes with a sensitivity of >99% and specificity of >98%.
The Tuberculosis Antibody Test Kit is designed to be used with Bioantibody’s TB100 test kit. It provides the same high-quality results as the TB100, but at a lower price.